Unit Not Heating Up, "On" Light Not Lit - Southbend SEZ/3 Operator's Manual

Super simple steam sez series countertop steamers
Table of Contents

Advertisement

SEZ S
C
ERIES
OUNTERTOP

Unit Not Heating Up, "ON" Light Not Lit

DISCONNECT POWER AT CIRCUIT BREAKER.
Check resistance between contactor terminals
(see Figure 8 on page 25).
measured resistance
consistent with the table
No
in Figure 8 on
page 25)?
Replace elements
and main fuses
(see Figure 9 on page
26).
O
S
TEAMERS
Unit not heating up, "ON" light not lit.
Check that circuit breaker is ON and that proper voltage
is available at main fuse block.
DISCONNECT POWER AT CIRCUIT BREAKER.
Remove control panel without disconnecting plug.
Reconnect power.
Turn lever to "ON" position. Actuate door switch.
Check voltage between A and B on control panel fuse
block (see Figure 7 on page 24).
Does voltage
No
match serial plate
Is
Yes
Check main fuses and
replace as needed
(see Figure 9 on page
26).
Test power switch or adjust so
that it is actuated properly by
cam on valve shaft. Replace
switch as necessary
(see Figure 10 on page 27).
'
M
1183437
PERATOR
S
ANUAL
T
ROUBLESHOOTING
Yes
voltage?
Check voltage on side C and D on control panel
fuse block (see Figure 7 on page 24).
Yes
Check voltage across
terminals 1 and 2 of
terminal block (see
Figure 7 on page 24).
Does voltage
No
match serial plate
voltage?
Does voltage
No
match serial plate
voltage?
Check for short circuit in
power switch (see
Figure 10 on page 27),
contactor and MOV
(see Figure 11 on page
28), and buzzer (see
Figure 12 on page 29).
Replace as necessary.
Replace control panel
fuses.
Yes
Replace "ON" light;
continue on next page.
P
19
AGE