General Data
Table 1 – General data CGAF 090-190 Standard Efficiency (continued)
Weights
FWD
Power supply
Shipping Weight (3)
Capacities
Operating Weight (3)
Cooling capacity on water (1)
Option Additional shipping weight
Heating capacity on water (2)
Fan motor
Single pump - Standard head pressure
Fan power input (3)
Single pump - High head pressure
Current amps (3)
Twin pump - Standard head pressure
Start-up amps
Air flow
Twin pump - High head pressure
minimum
Axitop option
nominal
XLN option
maximum
Main coil
Pump VFD option
Water entering/leaving connections
Partial heat recovery option
(Digit 19 = N)
Electric heater (accessory for blower only)
Partial heat recovery option
Electric power supply
(Digit 19 = P)
Heating capacity
Water Buffer tank option
Hot water coil (accessory for blower only)
Heating capacity (4)
System data
G2 filter (filter box accessory)
Nb of refrigerant circuit
Quantity
Minimum cooling load % (6)
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Standard/Partial Heat Recovery Unit
Quantity
R410A refrigerant charge
Dimensions ( LxWxth)
Circuit 1 / Circuit 2
Condensate pump (accessory)
Water flow - lift height
Oil charge Circuit 1 / Circuit 2

Not available for FWD30 and FWD45

Sound level (L/M/H speed)
POE Oil type
Sound pressure level (5)
Sound power level (5)
(1) Indicative performance at Evaporator water temperature : 12°C / 7°C - Condenser air temperature 35°C - for detailed performances, on a given unit,
Unit dimensions
consult Order Write Up.
Width x Depth
(2) Under 400V/3/50Hz.
Height
(3) Rated Condition without Pump Package.
Shipped unit dimensions
(4) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
Width x Depth
(5) If the power line of the unit is protected by fuses gG of the same size as the disconnect switch.
Height
Weight
Colour
Recommended fuse size
Unit alone (aM/gI)
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
4
12
Technical Data
CGAF
CGAF
90
100
SE
SE
08
(V/Ph/Hz)
(kg)
2085
2195
(kg)
2145
2260
(kW)
5,2
(kW)
6,3
(type)
(kg)
215
220
(kW)
0,23
(kg)
260
265
(A)
1,1
(kg)
300
305
(A)
3,2
(kg)
385
390
(m
/h)
490
3
(kg)
60
60
(m
/h)
820
3
(kg)
115
115
(m
/h)
980
3
(kg)
70
70
(type)
(kg)
45.00
45.00
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kg)
45.00
45.00
(kW)
2/4
(kg)
250
250
(kW)
6,3
#
2
2
2
%
23
25
(mm)
386x221x8
-
(kg)
18 / 18
19 / 19
(mm)
-
(type)
13.4 /
13.4 /
(l/h - mm)
(l)
13.4
13.4
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
CGAF
CGAF
CGAF
110
130
140
SE
SE
SE
12
20
230/1/50
2260
2325
2835
2330
2400
2915
8,3
15
11,9
18,9
2 x direct drive centrifugal
225
225
230
0,46
0,65
265
260
305
2,2
3,1
325
320
325
5,5
9,3
385
385
460
980
1400
60
60
80
1650
2300
115
115
150
1970
2600
70
70
70
ISO R7 rotating female
65.00
65.00
75.00
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
45.00
45.00
75.00
8
10
250
250
330
12
17,4
2
2
2
2
2
21
25
15
486x271x8
586x321x8
2
2
19.5 /
20.5 /
30 / 30
486x264x48
586x314x48
19.5
20.5
Centrifugal
13.4 /
13.4 /
23.1 /
24 - 500
13.4
13.4
22.1
OIL058E / OIL057E
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
CGAF
CGAF
CGAF
150
165
180
SE
SE
SE
30
45
3010
3075
3440
3100
3175
3550
18,8
30,1
20,9
38,2
230
295
310
1,04
1,51
305
305
320
4,7
5,5
325
440
450
14,1
16,5
460
465
480
1800
2700
80
80
100
3000
4500
150
150
150
3600
5400
70
70
70
75.00
75.00
75.00
1 1/2"
1 1/2"
400/3/50
400/3/50
75.00
75.00
75.00
12
12
330
330
330
22,4
34,5
2
2
2
2
2
17
15
14
586*421*8
586*621*8
2
2
32 / 32
33 / 33
38 / 38
586*414*48
586*614*48
23.1 /
23.1 /
23.1 /
23.1
23.1
23.1
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
CG-SVX039B-GB
UNT-PRC002-GB
CGAF
190
SE
3515
3630
305
320
450
475
100
150
70
75.00
75.00
330
2
17
39 / 38
23.1 /
23.1