Installation Requirements
Dimension and Weights
Dimensions details, dimensions of hydraulic
connections, electrical connections, isolator positioning,
specific features for heat recovery and free cooling
FWD
are included in submittals and diagrams provided in
Power supply
documentation package.
Capacities
Cooling capacity on water (1)
Heating capacity on water (2)
Center of Gravity
Fan motor
Fan power input (3)
See instructions on lifting drawings available on request.
Current amps (3)
Start-up amps
Unit Isolation and Leveling
Air flow
minimum
nominal
Provide a foundation with sufficient strength and mass
maximum
to support the unit operating weight (that is, including
Main coil
completed piping, full operating charges of refrigerant
Water entering/leaving connections
and oil, and water). Refer to unit operating weights.
Electric heater (accessory for blower only)
The unit must be leveled within 5 mm over its length
Electric power supply
and width. Use shims as necessary to level the unit. For
Heating capacity
additional reduction of sound and vibration, install the
Hot water coil (accessory for blower only)
Heating capacity (4)
optional elastomeric isolators.
G2 filter (filter box accessory)
Quantity
Elastomeric Isolators Installation
Dimensions ( LxWxth)
(Optional)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Isolators are ready to install. Mountings have to
Condensate pump (accessory)
be placed on a rigid and level foundation. External
Water flow - lift height
equipment should not transmit additional vibration to

Not available for FWD30 and FWD45

Sound level (L/M/H speed)
the chiller. The position of elastomeric isolator and
Sound pressure level (5)
weight per point are given in the Neoprene isolators
Sound power level (5)
installation drawing which is supplied with the chiller.
Unit dimensions
Width x Depth
Wrong placement along the unit may result in excessive
Height
deflection.
Shipped unit dimensions
Width x Depth
1.
Secure the isolators to the mounting surface using
Height
Weight
the mounting slots in the isolator's base plate.
Colour
Do NOT fully tighten the isolators mounting bolts at
Recommended fuse size
this time. See the isolators submittals for isolators
Unit alone (aM/gI)
Unit with electric heater (gI)
location, maximum weights, and isolators diagrams.
2.
Align the mounting holes in the base of the unit
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
with the threaded positioning pins on the top of the
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
isolators.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
3.
Install the unit on the isolators and secure the
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
isolators to the unit with a nut. The maximum
Heat exchanger operating limits:
isolators deflection should be 13 mm.
FWD:
*water temperature: max 100° C
4.
Level the unit carefully. Fully tighten the isolator
*absolute service pressure: min 1 bar/max 11 bars
mounting bolts.
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
Figure 2 – Elastomeric Isolator
*absolute service pressure: min 1 bar/max 11 bars
117.6
159
127
63.5
14.2
16
2
30
4
Technical Data
(V/Ph/Hz)
(kW)
(kW)
(type)
(kW)
(A)
(A)
(m
/h)
3
(m
/h)
3
(m
/h)
3
(type)
(Dia)
(V/Ph/Hz)
(kW)
(kW)
(mm)
(mm)
(type)
(l/h - mm)
(dB(A))
(dB(A))
(mm)
(mm)
(mm)
(mm)
(kg)
(A)
(A)
16 (2kW),25 (4kW)
9.6
40.6
70
4
6
Isolator Pads Installation (Optional)
Isolators are ready to install. Mountings have to
be placed on a rigid and level foundation. External
equipment should not transmit additional vibration to
08
12
the chiller. The position of pads isolator is given in the
pad isolators installation or selection drawing which is
5,2
8,3
supplied with the chiller.
6,3
11,9
Figure 3 – Isolator pads
0,23
0,46
1,1
2,2
3,2
5,5
490
980
820
1650
980
1970
3/4"
3/4"
230/1/50
230/1/50 or 400/3/50
2/4
8
6,3
12
2
2
2
RTAF 090_105_125_145_155_175
386x221x8
486x271x8
-
2
1
-
486x264x48
2
36/40/43
38/41/44
46/50/53
48/51/54
RTAF 190 HE_190 XE_190 HSE_205 HE_205 XE_205 HSE
890 x 600
1090 x 710
250
300
1
933 x 644
1133 x 754
260
310
32
46
8/16
8/16
40 (230V),3*16 (400V)
12.7
20
230/1/50
15
18,8
18,9
20,9
2 x direct drive centrifugal
0,65
1,04
3,1
9,3
14,1
90
1400
1800
2300
3000
2600
3600
ISO R7 rotating female
450
1 1/2"
1 1/2"
8
400/3/50
400/3/50
10
17,4
22,4
4
6
2
586x321x8
586*421*8
2
3
5
586x314x48
586*414*48
Centrifugal
24 - 500
4
6
46/50/53
47/52/57
56/60/63
57/62/67
1290 x 820
1290 x 970
350
3
5
1333 x 864
1333 x 1008
360
61
galvanised steel
8/16
8/25
3*20
3*25
30
45
30,1
38,2
1,51
4,7
5,5
16,5
2700
4500
5400
1 1/2"
400/3/50
12
12
34,5
2
2
586*621*8
2
2
586*614*48
8
47/52/58
57/62/68
1290 x 1090
450
650
7
1333*1133
460
660
76
118
8/25
3*25
CG-SVX039B-GB
UNT-PRC002-GB