Siemens SINUMERIK 828D Function Manual page 37

Sinumerik operate acceptance test
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

9. Make a selection in the bottom right of the default view to define whether the test (in this
case: SOS) was successful.
Figure 3-11
The test name is allocated a green checkmark if the test was evaluated to be positive. In
this case, you can either perform another test in the active setting area or you can initiate
the next test via the next setting area.
If the test was evaluated to be negative, then the test name is assigned a red cross and if
necessary, you can repeat the test.
Define which of the listed alarms should be subsequently documented in the acceptance
report.
Remove the check mark (left) for all alarms that should not be documented in the report.
10.Change the pre-assigned test names as required.
11.Press the "Next Test" softkey if you wish to start a test in the following setting area.
A test is created in the next setting area. A list of the necessary activities for this particular
test type is shown in the detailed display.
12.Follow the instructions on the screen (generally these involve steps 3 to 12).
After all tests of the individual setting areas have been performed, at the end, the "Finish"
setting area is displayed. In this setting area, you can generate the acceptance report from
the acceptance test and save it.
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC
3.2 SINUMERIK 828D/840D sl - drive-based Safety functions
Example - Safety acceptance test: SOS, evaluate result
Acceptance test wizard of SINUMERIK Operate
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents