Servicing
5.3.17 Replacing the ionisation electrode
Remove the air combination unit.
Loosen the plug-and-socket connection of the ionization
electrode.
Loosen screw (fig. 57, item 1) by a half-turn and slide bar
to remove.
Pull electrode to remove, and fit new unit.
Reassemble by following the above procedure in reverse.
5.3.18 Checking KIM connections
Locate Kim on the side of the UBA bracket.
Check if 4 pin connector (fig. 58, item 1) is fitted and
secure.
NOTE
This is not a servicable part and any fault
identified with this component, contact Boulter
Buderus.
Subject to modifications resulting from technical improvements!
Installation and maintenance instructions for wall-mounted condensing gas boiler Buderus 600 - 11R/19R/24R • 05/2004
Fig. 57 Replacing the ionisation electrode
Fig. 58 KIM connections
Boulter Buderus Ltd. • http://www.boulter-buderus.co.uk