8

ADVANCED COMMISSIONING

8.1
Enabling functioning of the
external temperature probe by
the remote control
Functioning with the external probe in the
boiler must be enabled if the remote control
(optional) is used.
Act on the programming of the REMOTE
control to enable its functioning if the re-
mote control (optional) is used.
• Press button
for more than 3 seconds to
enter in
mode.
0
21
3
1
8
6
9
1 5
1
2
Fig. 8.1
Press buttons
and
time to enter the transparent programming
(Fig. 8.2).
Fig. 8.2
• Press buttons
the "PM15" program that enables the ex-
ternal probe (Fig. 8.3).
- 62 -
ADVANCED COMMISSIONING
at the same
or
to display
Fig. 8.3
• Modify the programmed SET by pressing
buttons
or
60 is displayed, wait for the number pro-
grammed to flash (Fig. 8.4).
Fig. 8.4
• To exit programming, press button .
8.2
Setting the K coefficient of the
external temperature probe
The boiler is set with a K coefficient equal to
zero for boiler functioning without the probe
connected.
If the boiler is NOT EQUIPPED with the re-
mote control (optional) refer to Fig. 8.5.
until a setting of