Roof flue exhaust kit (Fig. 6.9)
This kit exhausts directly to the roof.
Coaxial pipe
Nominal height
Maximum height
Type C
33
Fig. 6.9
Extensions are available for reaching the
maximum height.
Bends at 90° and at 45° are available that
reduce the maximum total length of the
pipes by:
For the bend of 45° loss
For the bend of 90° loss
Pluming kit A (Fig. 6.10)
Coaxial Ø 60/100 mm + vertical part Ø 60
mm (flue outlet).
Coaxial Ø 60/100 mm (b) + vertical part
Ø 60 mm (a)
Telescopic coaxial flue
Maximum length (a + b)
This kit allows the products of combustion
to be discharged at a different location to
the air intake to avoid nuisance issues.
INSTALLATION
Ø 60/100
Ø 80/125
mm
mm
0.96 m
0.96 m
10 m
10 m
0.5 m
1 m
0.45-0.95 m
15 m
90° =--- 0,85 m
45° =--- 0,65 m
90°
Fig. 6.10
45°
60 mm elbows and extensions can be add-
ed to the vertical section.
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
For the bend of 45°
(60/100 mm) loss
For the bend of 90°
(60/100 mm) loss
For the bend of 45°
(60 mm) loss
For the bend of 90°
(60 mm) loss
Pluming kit B (Fig. 6.12) (Fig. 6.11)
Push on type Ø 60 mm vertical plume man-
agement kit
This kit allows the products of combustion to
be discharged at a different location, when
used with the standard horizontal flue kit.
ø 60 mm
90° =--- 1 m
ø 60/100 mm
45° =--- 0,5 m
0.5 m
1 m
0.65 m
0.85 m
- 47 -