Biasi ADVANCE OV Series User Manual And Installation Instructions page 48

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.11
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
For the bend of 45°
(60/100 mm) loss
For the bend of 90°
(60/100 mm) loss
For the bend of 45°
(60 mm) loss
For the bend of 90°
(60 mm) loss
The chart Fig. 6.12 gives the maximum al-
lowed value for a + b of (Fig. 6.11).
- 48 -
INSTALLATION
90° =--- 1 m
ø 60/100 mm
45°
=--- 0,5 m
0.5 m
1 m
0.65 m
0.85 m
"a" vertical length (m)
11
10
9
8
7
6
5
4
Allowed values
o
3
2
1
0
0
1
2
3
4
Fig. 6.12
A Plume deflector is available to assist in
overcoming boundary nuisance issues.
Fig. 6.13
d
u
5
6
7
8
9
10
"b" horizontal length (m)
11