Gas rate maximum
Natural G20
Propane G31
Gas rate minimum
Natural G20
Propane G31
Gas restrictors references
Natural G20
Propane G31
Air/gas mixer restrictors
Natural G20
Propane G31
Electrical data
Voltage
Frequency
Nominal Power consumption
Minimum Power consumption
Stand-by Power consumption
Protection degree
External fuse rating
Internal fuse rating
Flue design
Boiler type
B23P C13 C33 C43 C53 C63 C83
Ø Coaxial
Ø Twin split pipes
Ø Roof
Ø Roof
Nominal heat flow rate
(A) (E)
Exhaust temperature
(E)
Mass flow rate
(E)
TECHNICAL INFORMATION
m
/h
1,80
3
kg/h
1,32
m
/h
0,54
3
kg/h
0,40
Ø mm
/100
465
380
18 yellow
18 yellow
V~
230
Hz
50
W
24
W
11
W
3
IPX5D
A
3
N° 2 - 2
A
AF
mm
60/100
mm
80/80
mm
60/100
mm
80/125
kW
n.a.
°C
68,0
kg/s
0,0077
Flue gas figures
Nominal heat input
(A) (E)
CO
content with gas G20
2
O
content with gas G20
2
CO content with gas G20
Exhaust temperature
(E)
NOx class
Weighted NOx
Values refer tests with a 1 m flue working at the
(E)
nominal heat input
CO
contents
2
Nominal heat input
(A) (E)
CO
content with gas G20 (range
2
min - max)
CO
content with gas G31 (range
2
min - max)
Minimum heat input
(A) (E)
CO
content with gas G20 (range
2
min - max)
CO
content with gas G31 (range
2
min - max)
Other specifications
Height
Width
Depth
Weight (dry)
Water volume in the boiler (up to 1
bar)
(2072)
kW
n.a.
%
n.a.
%
4,1
ppm
106,0
°C
68,0
6
ppm
20
kW
17,0
%
9,0 - 9,6
10,0 -
%
10,6
kW
5,1
%
8,2 - 8,8
%
9,3 - 9,9
mm
700
mm
400
mm
290
kg
30,0
l (kg)
2,0