Mitsubishi a2 Series Programming Manual page 185

Simple application controller
Table of Contents

Advertisement

α
2 Simple Application Controllers
FB Name
Short
Message
Receiving
[SMR]
Short
Message
Receiving m
[SMRm]
Call Detect
[CD]
Call Detect
m
[CDm]
Random One
Shot
[ROS]
Delayed One
Shot
[DOS]
Delayed
Alternate
[DAL]
Retentive
Set/Reset
[RSR]
Control
Display
[CDP]
FB Symbol
Description of Function Block
The Shor t Message Receive Function
0
0
0
Block searches for the occurrence of a
E
P
O
command in the SM. In case the command
R
text is exactly included in the SM, outputs
S M R
are changed.
The Short Message Receive maintenance
Function Block searches for the occurrence
0 0
0
of a command in the SM. In case the
E
P
O
command text is exactly included in the SM,
R
outputs are changed. The function block
SMRm
c a n b e s e t u p f r o m t h e To p M e n u
"Parameter" via the front panel keys.
0
0
0
The Call Detect Function Block in case the
numbers of digits of both phone numbers
E
P
O
and the phone numbers itself are equal, the
R
CD Function Block output is switched on.
C D
The Call Detect Function Block in case the
numbers of digits of both phone numbers
0 0
0
and the phone numbers itself are equal, the
E
P
O
CD Function Block output is switched on.
R
The function block can be setup from the
CDm
TopMenu "Parameter" via the front panel
keys.
0 0
0
The Random One Shot Function Block
I
P
O
emits a random length single pulse to the
C
output.
R
O
S
0 0
0
The Delayed One Shot Function Block
I
P
O
emits a single pulse after a controlled delay
C
to the output.
D
O
S
0 0
0
The Delayed Alter nate Function Block
I
P
O
alternates the status of the output with each
C
pulse after a controlled delay.
D
A
L
The Set/Reset Function Block either holds
an output ON (set) or releases the output
OFF (reset.) Priority can be given to either
0 0
0
i n p u t p i n i f b o t h i n p u t s h a v e b e e n
S
P
O
energised. The default priority setting is
R
dedicated to the reset input pin. When the
R
S
R
power is turned OFF the function block will
use the last set or reset operation to control
the output.
The Control Display Function allows the
user to control the LCD image screens. The
f u n c t i o n b l o c k c a n o n l y b e s e t i n
AL-PCS/WIN-E software for
Controllers. When control bit N04 is ON, it
is possible to control the displayed User
Screen.
Memory
Use
*7
*7
30 Byte
30 Byte
19 Byte
20 Byte
16 Byte
14 Byte
α
*5
2 Series
8 - 7
Appendix 8
Section
6.31
6.31
6.32
6.32
6.33
6.34
6.35
6.36
6.37

Advertisement

Table of Contents
loading

Table of Contents