8.5.1

Avoidance of condensation or formation of condensation within the machine

● If the controller does not do this automatically, switch on any anti-condensation heating
● Do not switch on the anti-condensation heating for at least two hours after the motor has
Explosion hazard
If the anti-condensation heating is switched on directly after the machine is switched off, the
temperature class or the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
● Only switch on the anti-condensation heating after the motor has been switched off.
8.5.2

Avoidance of damage to roller bearings during stoppages

Extended stoppages at the identical or almost identical resting position of the roller bearings
can lead to damage such as brinelling or corrosion, for example.
● During stoppages, regularly start the machine up for a brief period once a month. As a
● During re-commissioning, refer to the information in the "Commissioning" section.
See also
Start-up (Page 95)
8.5.3

Measurement of the insulation resistance after an extended stoppage

Measuring the insulation resistance and polarization index (PI) provides information on the
condition of the machine. It is therefore important to check the insulation resistance and the
polarization index at the following times:
● Before starting up a machine for the first time
● After an extended period in storage or downtime
● Within the scope of maintenance work
SIMOTICS FD 1MM1
Operating Instructions 02/2019
during stoppages. This will avoid the formation of condensation.
been switched off. This prevents damage to the winding insulation.
WARNING
Carefully comply with the data on the anti-condensation heating plate.
minimum, rotate the rotor several times.
If you have uncoupled the machine from the driven machine and secured the rotor with a
rotor shipping brace, then remove this before turning the rotor over or starting the machine
up.
Make sure that the resting position of the roller bearings after the rotor has been turned over
is different from what it previously had been. Use the fitted key or the coupling halves as
reference markers.