Performance Specifications - Mitsubishi Electric MELSEC iQ-F Series User Manual

Programmable controller
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

2.3

Performance Specifications

The following table lists the performance specifications.
Items
EtherNet/IP
Class 1
communications
communications
Class 3
communications
UCMM
communications
Transmission
specifications
Network topology
*5
Hub
Connection cable
General-purpose
Transmission
Ethernet
specifications
communication
Protocol type
Number of connections
*5
Hub
Connection cable
Number of ports
Number of occupied I/O points
Applicable CPU module
Applicable engineering tool
Number of connectable units
Communication format
Number of connections
Communication data size
Connection type
RPI (communication cycle)
PPS (communication processing
performance)
Communication format
Number of connections
Communication data size
Connection type
Communication format
Number of connections (number of
simultaneous executions)
Communication data size
Connection type
Data transmission speed
Communication mode
Transmission method
Interface
IP version
Maximum segment length (Maximum distance
between hub and node)
Number of cascade
100BASE-TX
connections
*7
100BASE-TX
Data transfer speed
Communication mode
Transmission method
Interface
Maximum segment length (Maximum distance
between hub and node)
Number of cascade
100BASE-TX
connections
10BASE-T
*7
100BASE-TX
10BASE-T
Specifications
Standard EtherNet/IP
32
1444 bytes (per connection)
Point-to-point, multicast
2 to 60000 ms
3000 pps (case of 128 bytes)
Standard EtherNet/IP
*1
32
*2
1414 bytes (per connection)
Point-to-point
Standard EtherNet/IP
*1
32
*2
1414 bytes
Point-to-point
100 Mbps
Full-duplex
Base band
RJ45 connector
IPv4 is supported.
*3
100 m
*4
2 levels maximum
Star topology, line topology
*6
Hubs with 100BASE-TX ports
can be used.
Ethernet cable of category 5 or higher (STP cable)
100/10 Mbps
*5
Full-duplex or half-duplex
Base band
RJ45 connector
*3
100 m
*4
2 levels maximum
*4
4 levels maximum
Socket communication
Total of 32 connections
(Up to 32 external devices can access one FX5-ENET/IP module at
the same time.)
Hubs with 100BASE-TX or 10BASE-T ports
Ethernet cable of category 5 or higher (STP cable)
Ethernet cable of category 3 or higher (STP/UTP cable)
*9
2
8 points
• FX5U CPU module (Ver. 1.110 or later)
*10
• FX5UC CPU module
(Ver. 1.110 or later)
• GX Works3 (Ver. 1.050C or later)
• EtherNet/IP Configuration Tool for FX5-ENET/IP (Ver. 1.00A or
later)
1 module
2.3 Performance Specifications
*8
can be used.
2 SPECIFICATIONS
19
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx5-enet/ip

Table of Contents