Shrouds; Removing Shroud; Replacing Front Shroud - Invacare CometALPINE+ Service Manual

Table of Contents

Advertisement

The plugs on power module cannot be wrongly
connected because all plugs have a different size
and only fit in one socket.
10 mm wrench
17 mm wrench
Rubber hammer
Phillips screwdriver
Supporting wooden block
To adapt the drive program: programming
software or hand programming device and
controls system installation manual, available
from Invacare.
1. Secure mobility device against rolling away.
2. Place supporting wooden block under frames at
battery holder height.
3. Remove seat.
4. Remove shroud.
5.
Disconnect battery cable (1).
6. Remove rear wheel fixing screws.
7. Remove rear wheels.
8. Remove drive unit. See 5.10.1 Replacing drive unit,
page 30.
9. Remove screws (1) on power module (2).
Rhino1:
Fig. 5-7 DS112KB02/DS162KD01
Rhino 2:
1603798-D
Fig. 5-8 DS120
Fig. 5-9 DS160
10.
Replace power module (2).
11. Install parts in reverse order.
12. Load drive program onto power module. See controls
software description.
13. Test all functions (trial run).

5.6 Shrouds

5.6.1 Removing shroud

CAUTION!
Risk of damage to shroud
– Do not pull shroud straight up to remove.
– Follow instructions below.
1.
Place one hand at the front, the other at the rear of
the shroud A.
2. Lift shroud up from front.
3.
Place hands on left and right side of shroud.
4. Twist and lift to remove shroud completely.

5.6.2 Replacing front shroud

10 mm socket wrench
Phillips screwdriver
Service
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cometultra

Table of Contents