4.2.1 Entering setup (LCD Display)

This chapter applies for mobility devices with LCD
display.
1. Turn key to switch mobility device off.
2.
Press and hold keys.
3. Turn key to switch mobility device on.
Mobility device enters setup mode after two seconds.

4.2.2 Setting counter

This chapter applies for mobility devices with LCD
display.
10
<50%
<35%
<25%
<20%
Enter next display with
key.
Enter next display with
key.
Enter next display with
key.
1. Enter setup settings as described in 4.2.1 Entering
setup (LCD Display), page 10.
Default setting is 0. You can set a km value
as service interval.
If counter value is greater than set value,
will flash for one minute, when key is switched on.
+
-
2.
Press and hold key for 2 sec. to erase counter.
3.
Press key to increase value.
4.
Press key to decrease value.
5.
Press key to save and enter next page.

4.2.3 Setting Battery Gauge

This chapter applies for mobility devices with LCD
display.
Setting battery gauge is mandatory when
retrofitting operating console.
Adjust the parameter in battery gauge to suit different
types and sizes of batteries.
AGM battery
(1) small
(2) big size
size
batteries
batteries
(> 50 Ah)
(≤ 50 Ah,
default)
symbol
0 (OFF)+ 500 + 1000
+1500 + 2000 ..........
+ 9500 + 9999 (max)
9999 – 9500 – 9000
– 8500 – 8000 .........
– 500 – 0 (OFF)
Gel battery
(3) small
(4) big size
size
batteries
batteries
(> 50 Ah)
(≤ 50 Ah)
1603798-D