Error messages

Error message
BATTERY LOWER-LEVEL
LOW BATTERY
MEMORY FULL
FILE FULL
FILE DAMAGED
FORMAT ERROR
PROCESS ERROR
Cause/Remedy
You cannot format the memory or erase all the files in a folder
because of insufficient battery power. Prepare a new battery to
replace the current one.
Battery is exhausted. Replace the old battery with a new
one. Or charge the rechargeable battery or replace the old
rechargeable battery with a new one.
The remaining memory capacity of the IC recorder is
insufficient. Erase some messages before recording.
When there are already 99 messages in the selected folder or
the total number of the file stored in the IC recorder becomes
maximum, you cannot record a new message. Erase some
messages before recording a message.
You cannot play or edit messages, because the data of the
selected file is damaged.
The IC recorder cannot be turned on using the computer
because there is no copy of the control file required for
operation. Format the IC recorder using the formatting
function in the menu.
The IC recorder failed in memory access. Remove and then
re-insert the battery.
Save a backup copy of your data and format the IC recorder
using the menu.