8.3. Wiring

Caution
To prevent damage, all power for the SI Unit and modules must be turned off (i.e. de-energized)
before the modules are installed or removed.
For a protection rating of IP65 to be ensured, all covering caps must be screwed down correctly
after wiring and setting have been performed.
For a protection rating of IP65 to be ensured, sockets that are not used must be fitted with the
Seal cap.
Pin allocation of the M12, 5 pins socket connector as shown in the following table:
Pin
1
N.C.
2
DO (output signal "n+1")
3
0 V (valves/loads)
4
DO (output signal "n")
5
FE/Shield

8.4. Process data

The EX245-DY1 occupies 1 byte of output data. The following table shows the allocation of the
digital outputs and the process image.
Connector position
Connector designation
Output
Table. 8-2 Pin allocation of the connector for EX245-DY1
Allocation
Table. 8-3 Digital output allocation and the process data
Pin 2
Pin 4
View of connector (module side)
X0
X1
X2
Bit 1
Bit 3
Bit 5
Bit 0
Bit 2
Bit 4
- 50 -
2
5
1
3
4
X3
Bit 7
Bit 6
No.EX※※-OMW0011-A