(3) Safety stop function operation
Input signal
Input power
S1-SC
S2-SC
OFF
- - -- -
Short
Short
Open
Open
ON
Short
Open
Open
Short
∗1
ON: Transistor used for an open collector output is conducted.
OFF: Transistor used for an open collector output is not conducted.
For more details, refer to the Safety stop function instruction manual (BCN-A211508-000).
Output signal
Failure
SAFE
∗1
- - -- -
- - - --
OFF
No failure
OFF
Detected
OFF
No failure
ON
(SA)
Detected
OFF
Detected
OFF
(E.SAF)
Detected
OFF
(E.SAF)
Operation state
SAFE2
∗1
OFF
Output shutoff (Safe state)
ON
Drive enabled
OFF
Output shutoff (Safe state)
ON
Output shutoff (Safe state)
OFF
Output shutoff (Safe state)
OFF
Output shutoff (Safe state)
OFF
Output shutoff (Safe state)
Wiring
2
23

Hide quick links: