Section 16
Monitoring
100 MVA
242/15,65 kV
100MVA
15,65kV
IEC09000041-1-EN V1 EN-US
Figure 189: Single line diagram for generator application
In order to measure the active and reactive power as indicated in figure 189, it is necessary to
do the following:
1.
Set correctly all CT and VT data and phase angle reference channel
section "") using PCM600 for analog input channels
2.
Connect, in PCM600, measurement function to the generator CT & VT inputs
3.
Set the setting parameters for relevant Measurement function as shown in the following
table:
384