Filter Backwash Time (Filter Mode Only)
If the system is set up as a filter, the brine amount is unnecessary. The controller deactivates the brine
amount setting, and changes to an adjustable backwash time in minutes.
A
Press
.
→ Time flashes.
B
Adjust displayed time with
→ Default time: 14 minutes.
→ The controller can be adjusted from 0 to 99 minutes for backwash.
C
Press
to validate the selection and advance to the next parameter using

6.3.8. Estimated capacity

A
Note
The system capacity is displayed in kilograms equivalent CaCO
before a regeneration is necessary.
A
Note
Value is derived from the system's resin volume input and salt amount input.
A
Note
The capacity is displayed for information purposes on the 740 controller. It cannot be
changed.
Set the estimated capacity on the 760 controller.
A
Press
.
→ The amount number flashes.
B
Adjust displayed capacity with
C
Press
to validate the selection and advance to the next
parameter using
A
Note
If using the 740 controller, programming is complete. The controller will return you to the
normal operation mode.

6.3.9. Hardness (760 on-demand controller only)

Set inlet water hardness at installation site.
A
Press
.
→ The hardness number flashes.
B
Adjust displayed hardness number with
→ Default hardness setting is 250 mg/L equivalent CACO
C
Press
to validate the selection. Initial programming is now
complete. The controller will return you to the normal
operation mode.