6.3.4. Regeneration time

Set the time when regeneration will take place.
A
Press
.
→ Regeneration time flashes.
B
Adjust displayed time with
C
Default setting: 2:00am.
D
Press
to validate the selection and advance to the next
parameter using

6.3.5. Days to regenerate (740 time-clock controller only)

Set number of days between time-clock regeneration (regen frequency).
A
Press
.
→ Number of days flashes.
B
Adjust displayed number with
→ Default number: 3 days.
→ Days can be adjusted from ½ (.5) to 99 days.
C
Press
to validate the selection and advance to the next
parameter using

6.3.6. Calendar override (760 on-demand controller only)

Set number of days for calendar override on-demand controller.
A
Press
.
→ Number of days flashes.
B
Adjust displayed number with
→ Default time for calendar override: 0 day.
→ Days can be adjusted from ½ (.5) to 99 days.
C
Press
to validate the selection and advance to the next
parameter using

6.3.7. Amount of brine used per regeneration

Set desired brine amount. 3 salt settings are available on 740 and 760 controllers:
S – Standard Salt – 120 grams/liter of resin.
H – High Salt – 200 grams/liter of resin.
L – Low Salt – 40 grams/liter of resin.
A
Press
.
→ Setting flashes.
B
Adjust displayed settings with
→ Default setting is "S" standard salting.
C
Press
to validate the selection and advance to the next
parameter using