Setting Rf Power - Shure Microflex MXV Series User Manual

Wireless system
Table of Contents

Advertisement

Caution: Audio is temporarily interrupted during spectrum scan. Do not initiate a scan during a live meeting.
Running Spectrum Scans
1.
Dock all microphones in chargers to decrease MXW affect on the RF spectrum.
2.
Open the Web Discover application and view all APTs on the network.
3.
Open each APT web application and go to the monitor tab.
4.
Start a scan on all APTs and let them run at the same time for at least 15 seconds. This analyzes the spectrum and se­
lects the best channel to operate on.
5.
Stop the scan, and check for detections. If you do not show any PHS error, the system is ready to go.
6.
If PHS error persists, repeat the scan up to 3 times.
7.
If PHS detection persists through 3 or more spectrum scans, the signal is most likely coming from the PHS network.
Switch your systems to PHS Exclusion mode to operate reliably on fewer channels.
Tip: Resolved detection notifications should not reoccur until a new spectrum scan is initiated, either manually or by rebooting/
power cycling the system.

Setting RF Power

The RF radius of a configuration can be limited to allow another MXW system to re­use the frequency time­slots. It is best prac­
tice to use the lowest setting that supports the installation. Perform a walk-around test with the transmitters to ensure that the
coverage setting is sufficient.
The RF Power is set from the Preferences tab of the control software. The setting applies to each access point in the Configu­
ration. Reference the following table for setting the RF Power.
RF Power Levels
Setting
Max
High
Medium (default)
Low
Transmitter Power (mW)
80
16
3
1
Coverage Distance from
APT
150 ft
100 ft
50 ft
25 ft
Shure Incorporated
Typical Application
Ballroom and auditorium
spaces
Large meeting spaces and
lecture halls
Conference, training and
multipurpose rooms
Small video-conference
rooms and boardrooms
59/103

Advertisement

Table of Contents
loading

Table of Contents