6.0 Maxxus Power Requirements

®
Sundance
hot tubs are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
However, they are shipped factory configured for their most common
preferred electrical connection as follows:
North American 60Hz Model:
Export 50Hz Model:
If you prefer, a qualified technician can perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see table below).
Voltage
Max. Current Draw
Number of Wires
Circuit Breaker (2-Pole)
In this configuration, the heater will not operate while any two jets
*
pumps are running.
In this configuration the heater will operate while any two jets
**
pumps and the blower are running but will not operate when all
three jets pumps are running.
Voltage
Max. Current Draw
Number of Wires
Circuit Breaker (2-Pole)
In this configuration, the heater will not operate while any two jets
*
pumps are running.
In this configuration the heater will operate while any two jets
**
pumps and the blower are running but will not operate when all
three jets pumps are running.
North American 60Hz Maxxus
Export 50Hz Maxxus
240VAC/60A
230VAC/45A
240V/50A*
240VAC
38A
3
50A*
240V/45A*
230VAC
34A
3
45A *
240V/60A**
240VAC
48A
3
60A**
240V/50A**
230VAC
42A
3
50A **