Power Requirements

Sundance Spas hot tubs are designed to provide optimum
performance and flexibility of use when connected to their
maximum electrical service. However, they are shipped
factory configured for their most common preferred
electrical connection.
If you prefer, a qualified technician can perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see table below).
7.1

North American 60 Hz Power Options

Voltage
Max. Current Draw:
Frequency:
Number of Wires:
Circuit Breaker (2-Pole):
In the 40A configuration, the heater will not operate while any jets
*
pump is running.
In the 50A configuration, the heater will operate when one jets pump is
**
running, but will not operate while two jets pumps are running. This is
the factory default setting.
*** In the 60A configuration, the heater will operate while two jets pumps
are running.
Page 16
North American 60 Hz
240 VAC
28A
60 Hz
3
40A*
240 VAC
39A
60 Hz
3
50A**
240 VAC
48A
60 Hz
3
60A***