Important Heater Details:
The maximum temperature for which the hot tub can be set is
104°F (40°C) and the minimum is 80°F (27°C).
For Altamar, Cameo, Capri, Optima, Majesta, and Marin hot tubs
powered with a 40 amp service, turn off jets pump #1 and jets
pump #2 to operate heater.
Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed "set
temperature", then turns off. The heater will reactivate after the
water cools to approximately 1° below the "set temperature."
8. Place Cover On Hot Tub
Keeping the insulating cover in place anytime the hot tub is not in
use will reduce the time required for heating, thereby minimizing
operating costs.
The time required for initial heat-up will vary depending on the start-
ing water temperature.
DANGER: Risk of injury, always check water tempera-
ture carefully before entering hot tub!
Decontamination Procedure (Steps 9-15)
Steps 9-15 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after
performing steps 1-6 above.
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table (page 18) for approximate water fill volume by
model.
CAUTION: Never add chlorine tablets (trichlor) to your
hot tub for any reason! This chemical may damage com-
ponents within your hot tub and void the manufacturer
warranty.