4. Move the height of the needle bar (2) such that the hook tip (3) is in
Important
Do not twist the needle to the side.
The groove (4) must face toward the hook.
5. Tighten the screw (1).
6. Remove the lock.
7. Check the height of the needle bar at maximum stitch length when
60
the middle of the lower third of the groove (4) for the needle.
sewing forward and in reverse; adjust it again if necessary.
Position of the hook and needle
Service Instructions 969 - 06.0 - 03/2019