Code
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3150
3151
3155
3160
3215
3216
3217
3218
110
Possible cause
AC-RDY timeout, intermediate
circuit voltage did not reach
the defined threshold in the
specified time
High voltage fault, mains
voltage, longer duration
>290 V
Low voltage failure
nd
(2
threshold) (mains voltage
< 150 V AC)
Low voltage warning
st
(1
threshold) (mains voltage
< 180 V AC)
Pedal is not in position 0
U24 V short circuit
2
U24 V (I
T) overload
Pedal not connected
Speed limited due to
insufficient mains voltage
Operation lock
Maintenance necessary
Maintenance necessary
(operation cannot continue
unless parameter t 51 14 is
reset)
No release for sewing process • Parameter t 51 20 - t 51 33
Stitch loosening device
Bobbin stitch counter (info
value 0 reached)
Remaining thread monitor left • Change the left bobbin
Remaining thread monitor
right
Remaining thread monitor left
and right
Troubleshooting
Remedial action
• Check mains voltage
• If the mains voltage is OK,
replace the control
• Check mains voltage
• If nominal voltage is
continuously exceeded, stabilize
it or use a generator
• Check mains voltage
• Stabilize the mains voltage
• Use generator
• Check mains voltage
• Stabilize the mains voltage
• Use generator
• When switching the control on,
take your foot off the pedal
• Disconnect 37-pin plug; if error
persists, replace control
• Test inputs/outputs for 24 V
short circuit
• One or several magnets
defective
• Connect analog pedal
• Check mains voltage
• Check tilt sensor on machine
• Lubricating the needle bar
• Service is required  p. 99.
= 25
• Stitch loosening cannot be
performed
• Change bobbin, set counter
value
• Change the right bobbin
• Change the left and right bobbin