10.4.5 Clean Air Cleaner

Check and remove any debris from the foam
cover of the air cleaner daily before each use.
Thoroughly clean or replace the foam cover every
three months or 50 hours of operation (clean it
more frequently when used in dusty conditions).

10.4.6 Engine Circuit Protection

The circuit protector protects the battery charging
circuit. A short circuit, or a battery connected with
reverse polarity, will trip the circuit breaker.
The green indicator inside the circuit protector
will pop out to show that the circuit protector has
switched off. If this occurs, determine the cause
of the problem, and correct it before resetting the
circuit protector.
Push the circuit protector button to reset.
40
10.5 ENGINE ACTUATOR REPLACE-
MENT

10.5.1 Actuator Removal

WARNING
CRUSHING HAZARD
Ensure the seed tender is blocked to
prevent movement.
Ensure the engine is not running and
remove the key during the following
procedures. Serious injury or death
can result from being caught in moving
parts.
1. Disconnect the actuator cable from the engine
harness at connector (1).