Step 3: Select destination memory and direction from base coordinate
MSB
R#45
Step 4: Execute the command
MSB
R#46
Step 5: Check for command completion
CPU should check CE bit of status register S#2 to identify if VDP has completed
execution of the command. When command is being executed, CE bit is set to 1; when
command is complete, CE bit will be reset to 0.
© 1985 ASCII CORP. / NIPPON GAKKI CO.
7
6
5
0
-
MXD
7
6
5
1
0
0
4
3
2
-
DIY
DIX
4
3
2
0
-
-
Page 84 of 108
1
0
LSB
-
-
0: Right
X transfer
direction
1: Left
0: Down
Y transfer
direction
1: Up
0: VRAM
Destination
select
1: ExpRAM
1
0
LSB
-
-
LMMV cmd
© 2010-2015 Eugeny Brychkov