Pre-Installation Check; Mechanical Installation - BEA R2E-100 User Manual

Active infrared, request-to-exit sensor – dual relay output
Table of Contents

Advertisement

3 Component ID
LEFT END CAP
4 Precautions
‰ Shut off all power going to header before attempting any wiring procedures.
‰ Maintain a clean and safe environment when working in public areas.
‰ Constantly be aware of pedestrian traffic around the door area.
‰ Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
‰ ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board,
ensure you dissipate your body's ESD charge.
‰ Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
‰ Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
‰ DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA,
Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

5 Pre-Installation Check

1.
When preparing to wire multiple devices together for a system configuration, it is best to ensure the correct operation of each device
independently before starting, to help reduce troubleshooting time later in the event of a discrepancy.
2.
Prior to installing any equipment, ensure correct line voltage and stability. When applying equipment on a new installation which utilizes new
electrical supply circuits, always ensure that correct line voltage exists and is stable. Remember to shut off the power after this is checked
and before performing any wiring to the system.

6 Mechanical Installation

To prepare the R2E-100 for mounting to the header, perform the following:
1.
Remove only the right end cap from the R2E-100 (Picture 1). It is attached by one Phillips head screw.
2.
Remove the lens from R2E-100 by simply sliding it out at the right end of the housing approximately a 1/4 inch and then gently pull the lens
down and away from the housing (Picture 2).
1
3.
Slide the PCB (printed circuit board) and plastic clips out of the housing and set them aside (Picture 3).
©BEA
©BEA
| Original Instructions
| Original Instructions
75.5644.09 R2E-100 20181009
75.5644.09 R2E-100 20181009
HOUSING
LENS
2
3
4 FOOT CABLE
RIGHT END CAP
NOTE: The R2E-100 and any connected devices must be mounted inside
the protected area to be compliant with UL294/ULC-S319.
Page 2 of 10
Page 2 of 10

Advertisement

Table of Contents
loading

Table of Contents