UL/ULC SPECIFIC NOTES:
For UL 294 Listed installations, the R2E-100 should only be powered by a UL 294 Listed, power limited power supply, as well as
connected to a UL Listed electronic locking (EL) device and associated access control hardware.
For CAN/ULC-S319 Listed installations, the R2E-100 should only be powered by a ULC-S319 or ULC-S318 Listed, power limited
or Class 2 power supply or Canadian Class 2 transformer, as well as connected to the following ULC-S319 Listed devices such as
a Control Panel, an electronic locking (EL) device, a card reader/keypad, and the Door/REX/ Momentary switches.
BEA carries two UL listed power supply products:
• BEA PN 10PS12-24 – 12VDC or 24VDC @ 1.75A (Altronix AL175UL – UL 294 listed Power Supply Unit 39BA – CUL listed
CSA Stan
• BEA PN 10PS12-24D – 12VDC or 24VDC @ 1.75A with battery backup (Altronix AL175ULX – UL 294 listed Power Supply
Unit 39BA –
BEA carries several UL listed maglock products:
• BEA PN 10MAGLOCK1UL – single 1200lb electromagnetic lock (UL and CUL listed – File# S24600)
• BEA PN 10MAGLOCK3UL – single 600lb electromagnetic lock (UL and CUL listed – File# S24600)
• BEA PN 10MAGLOCK5UL – double 1200lb electromagnetic lock (UL and CUL listed – File# S24600)
• BEA PN 10MAGLOCK6UL – double 600lb electromagnetic lock (UL and CUL listed – File# S24600)
An example of the UL294 control panel, card reader, REX and Door switches:
• GE ACU2, ACU2X, ACUXL Controller (UL-294 listed – File# BP5721)
• HID Card Reader Model 83120B (UL-294 listed – File# BP6568)
• Securitron Request to Exit Switch PN EEB2 (UL-294 listed - File# BP7041)
• GE Door Position Switch PN 1125W-N (UL listed)
The three inputs to the R2E must be used as a "Dry Input" with no voltage applied from the Card Reader, REX, or DPS.
The use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer or manufacturer's
representative will invalidate the CAN/ULC-S319 certification.
For UL 294 and NFPA 101 sections 7.2.1.6.2.1 wire the lock for fail safe condition for the loss of power.
The audible sounder on the device is not intended as a burglary alarm.
The maximum detection range is 4 feet.
CAN/ULC-S319 limits the rated output of the audible signal device (stated as a Sound Pressure Level (SPL) from 70 dBA to a
maximum of 100 dBA at 1 meter.
UL-294 limits the rated output of the audible signal device to a minimum of 85 dBA at 10 feet.
When used with electric strikes on supervised portals, request-to-exit devices shall by-pass portal alerts caused by exiting. When
used with electromagnetic locks on supervised portals, request-to-exit devices shall signal the access control unit to release the
electromagnetic locks as well as to by-pass portal alerts caused by exiting.
For UL 294 / Canadian ULC-S318: Electronic Security Device Inc. PN: SPS-3.3, 24VDC – 3A - Supervised Power Supply/Charger
module, Universal Input: 85vac–260vac, ULC File Number UTRZ8.S8102 (UL-294 listed - File# BP9019)
For Canadian Class 2: Signal Transformer Company PN: CL2-25-
24, Dual primaries, 115/230 V, 50/60 Hz, Secondary: 24V @ 1.05A,
Secondary Fuse Required 1.5A Non-inherently limited, ULC File
Number: XOKV8:E116583
©BEA
©BEA
| Original Instructions
| Original Instructions
75.5644.09 R2E-100 20181009
75.5644.09 R2E-100 20181009
dard C22.2 No. 205-M1983 – File# BP5864)
CUL listed CSA Standard C22.2 No. 205-M1983 – File# BP6714)