ELECTRICAL
1.
INSTALLATION
ELECTRICAL
Perform the following for wiring the Wizard to an automatic door control:
INSTALLATION –
WIRING
Wizard Wire
Color
Red
Black
White
Green
Brown
Blue
Other Wiring Notes:
1.
FOR CONTROLS WITH ONLY AN ACTIVATION INPUT:
Two options exist for this configuration. First the White and Green may be connected to Brown and Blue
(respectively), OR the Relay Configuration may be set to a value of 5 or 6, in which case ONLY the White
and Green wires are used.
2.
75.5101 V1 Sep. 2003 [Rev. 9/22/2003]
With Wizard in place, locate the enclosed cable and feed the stripped end through the wire passage
hole in header from the Wizard side as shown in Picture (F). Leave enough slack to allow connection
to the Wizard and proper routing of wire around the plastic posts (E). Please observe proper routing
of the cable as shown – this is to divert rainwater from the Wizard if it should run down the cable, and
also provides for proper routing to allow easy cover installation on the Wizard.
E
Connect To:
Microprocessed Controls
12 to 24 VAC / VDC: -5% to +10%
12 to 24 VAC / VDC: -5% to +10%
Common at Door Control
Activation Input at Door Control
Common at Door Control
Safety Input at Door control
When connecting to a microprocessed control box, the Motion output and presence output wires may
be connected to separate inputs or may also be to a mutual input, as some controls may only have
an activation input, while others may have an activation input, as well as a safety (or presence) input.
For example:
WIZARD
Red - 12 to 24 VAC / VDC: -5% to +10%
Black - 12 to 24 VAC / VDC: -5% to +10%
White – Common at Door Control
Green – Activation at Door Control
Brown
Blue
WIZARD
Red - 12 to 24 VAC / VDC: -5% to +10%
Black - 12 to 24 VAC / VDC: -5% to +10%
White – Common at Door Control
Green – Activation at Door Control
Brown – Not Used
Blue – Not Used
If separate outputs are available at the control box, White and Green may go to common and activation,
while Brown and Blue will go to the safety (or presence) input. Always respect polarity with Brown and Blue.
Wire fed
F
through
towards
control
WIZARD
MOUNTING
TEMPLATE
Plastic post
to wrap wires
around
Connect To:
Old Style Controls
12 to 24 VAC / VDC: -5% to +10%
12 to 24 VAC / VDC: -5% to +10%
Common at Door Control
Activation Input at Door Control
Brown & Blue wires are not used for SN
52000 and greater – Do NOT Connect
Them To Anything:
All output is through the white and green
wires. The Wizard MUST be programmed
to a Relay Configuration value of 5 or 6.
See Page 8. Wizards below SN 52000 will
still require a 10IFBWIZARD.
OR
+
For SN 52000 and greater,
program the Wizard to Relay
Configuration Value 5 or 6. If
set to 5, contacts close upon
detection. If set to 6,
contacts open upon
detection.