SUPERSCAN
INFRARED PRESENCE BEAM
INSTRUCTION MANUALFOR INDUSTRIAL APPLICATIONS
We can be reached from anywhere in the world:
US & Canada Toll Free 800-523-2462 (EST)
US & Canada Toll Free 877-232-9378 (PST)
Mexico Toll Free 001-800-711-1398
Latin America 412-782-5191
Email: sales@beainc.com
B.E.A., Inc. 300 South Main Street Pittsburgh PA 15215
USA Tel. 412-782-5150
Fax 412-782-5154
This manual may be downloaded from our web site in PDF format: www.beainc.com
Requires Adobe Acrobat Reader.
75.1035 V1 Feb 2001

Advertisement

Table of Contents
loading

Summary of Contents for BEA Superscan

  • Page 1 SUPERSCAN INFRARED PRESENCE BEAM INSTRUCTION MANUALFOR INDUSTRIAL APPLICATIONS We can be reached from anywhere in the world: US & Canada Toll Free 800-523-2462 (EST) US & Canada Toll Free 877-232-9378 (PST) Mexico Toll Free 001-800-711-1398 Latin America 412-782-5191 Email: sales@beainc.com B.E.A., Inc.
  • Page 2 This means that the zone can be directed closer or farther away from the face of the door. Each SuperScan module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently of the other modules. The transmitter emits an extremely precise beam, which measures approximately 4" in diameter at a distance of 8'.
  • Page 3 For applications where a door opens at two different heights, the SuperScan can be used for activation. By mounting the SuperScan’s as show to the right, if the beam on the side of the door is broken, the door will only open partially.
  • Page 4 SuperScans. Use the supplied door loop to secure the wiring coming out of the SuperScan housing at the end cap and also at the entry point at the jamb tube as shown on drawing.
  • Page 5 Please use the above diagrams for the terminology used to describe the installation of the SuperScans. The position of the master and slaves in the aluminum extrusion is important to the operation of the SuperScan unit. The correct position of the Master/Slave combination is Master on the Hinge side of the door and the Slave on the Leading edge side of the door.
  • Page 6 B.E.A.'s SuperStop Module. The J1 function must be set on each module. Function J2: Relay Mode J2 is a two-position jumper, which enables either a passive or active relay to be selected. The SuperScan comes factory preset with the relay in the ACTIVE MODE.
  • Page 7 PASSIVE RELAY: The relay is de-energized when the detector is at rest 1. NORMALLY OPEN: Use NO & COM terminals (4 & 6) & CHANGE JP2 from the factory preset position. 2. NORMALLY CLOSED: Use the NC & COM terminals (5 & 6) & CHANGE JP2 from the factory preset position. Potentiometer P1: Hold Time Adjustment The hold time adjustment is altered by the turn of a potentiometer, and refers to the amount of time the output may...
  • Page 8 SuperScan Terminals NOTE USED NOT USED NOT USED 4 (NO) In the relay mode, depending on the position of JP2 this terminal will provide either a NO or NC contact. Please see page 9 for further explanation. 5 (NC) In the relay mode, depending on the position of JP2 this terminal will provide either a NO or NC contact.