Summary of Contents for Ferroli AQUA1 PLUS

  • Page 1 AQUA PLUS Scaldacqua a pompa di calore Water heaters heat pump Les chauffe-eau pompe à chaleur Calentadores de agua bomba de calor...
  • Page 2 FERROLI S.p.A Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years of experiences and of particular research studies and has been made with top quality materials and advanced technologies. The CE mark guarantees that the products satisfy all the applicable European Directives.
  • Page 3: Table Of Contents

    SOMMARIO General specification ..........................3 CONSIGNMENT OF THE MACHINE ..............................3 FOREWORD ......................................3 IMPORTANT INFORMATION .......................... 3 CONFORMITY WITH EUROPEAN REGULATIONS ........................3 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES ......................3 LIMITATIONS OF USE ................................... 3 OPERATING LIMITS ....................................4 FUNDAMENTAL SAFETY RULES .................................
  • Page 4: General Specification

    IMPORTANT INFORMATION General specification Conformity with European regulations Consignment of the machine The present heat pump is a device intended for As soon as the machine is consigned, it is essential for domestic use in conformity with the following the user to make sure that he has received all the items European directives: indicated on the consignment note and that the 2012/19/UE Directive on general product...
  • Page 5: Operating Limits

    Manuale utente Operating limits Below, term “start” intends switching from the Stand-by to the ON The above mentioned device is intended to be status; the term “switch off” intends the used exclusively for the heating of domestic hot switching from the ON to the Stand-by water within the foreseen limitations of use.
  • Page 6: Operating Logic

    Manuale utente temperatures is the degree When the equipment is switched on, it Celsius shows the status it was in when it was previously switched off. Degree this lit: unit Fahrenheit LED measurement 3.1.1.2 The [SET]key temperatures is the degree Fahrenheit.
  • Page 7: Basic Management

    Manuale utente in the event that a temperature exceeding If the keyboard has been locked or an 56°C is required; advanced procedure is in progress, it will ECONOMY operating mode not be possible to carry out the normal switching on/off of the equipment. This mode uses only the renewable energy of the heat pump without ever enabling the Every time the equipment is switched on,...
  • Page 8 Manuale utente Make sure that the keyboard is not locked 3.1.3.4 Set point setting and that no other advanced procedure is in progress; By specific procedures described below the Press and release the key: “SP1” will set points SP1, SP2 and SP3 can be changed. be shown on the display;...
  • Page 9 Manuale utente Make sure that the keyboard is not locked To start the procedure: and that no other advanced procedure is in Make sure that the keyboard is not blocked progress; and that no other advanced procedure is in Press and release the key: the display will progress;...
  • Page 10 Manuale utente To silence the alarm, carry out the following Minimum temperature alarm procedure: Solution: Make sure that no other advanced procedure - Check the temperature associated with the is in progress; alarm; Press any key once. - Parameters displayed: A0, A1, A2 and A11. Main consequences: ADVANCED MANAGEMENT - The equipment will continue to work as...
  • Page 11: Maintenance And Cleaning

    Manuale utente MAINTENANCE AND CLEANING 3.1.3.14 Error messages Error in probe in upper part of the boiler WARNING! Any equipment repair must Solutions: be performed by qualified personnel. - Check that the type of probe is in conformity Improper repairs can put the user in with parameter P0 settings;...
  • Page 12 Manuale utente Mod.200-260 LT Fig. 5 – Lower panel removal Fig. 4a – Resetting of safety thermostat Clic Mod.160-200-260 HT Fig. 4b – Resetting of safety thermostat Fig. 6 – reset of the safety thermostat For the mod. 90 WARNING! The tripping of the safety thermostat can be caused by a fault linked to the control board or by the Disconnect the device from the mains power...
  • Page 13: Control Le Dispositif Contre Les Surpressions

    Manuale utente In the upper part of the equipment there is a Control le dispositif contre les surpressions ventilation filter. This must be periodically cleaned Il faut faire fonctionner régulièrement le dispositif in order to maintain the perfect efficiency of the contre les surpressions au moins tous les 30 jours system.
  • Page 14: Magnesium Anodes

    Manuale utente water connection (previously removed to allow Magnesium anodes the emptying of the boiler) filling and pressurizing magnesium anode (Mg), also called the boiler in order to verify that no water losses are "sacrificial" anode, avoids any parasitic currents incurred in the area where the maintenance that are generated inside the boiler that can intervention has been carried out.
  • Page 15: Emptying The Boiler

    Manuale utente Problem Possible causes The heat pump does There is no electricity; not work The plug is not correctly Mg Anode inserted in the socket. The compressor and/or The set safety period of the fan do not work time has not finished; scheduled temperature has been reached.