ABB ACS800 Series Firmware Manual page 171

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

Table 17 Limit Word 1 (Actual Signal 02.23).
Bit
Name
0
TORQ MOTOR LIM
1
SPD_TOR_MIN_LIM
2
SPD_TOR_MAX_LIM
3
TORQ_USER_CUR_LIM
4
TORQ_INV_CUR_LIM
5
TORQ_MIN_LIM
6
TORQ_MAX_LIM
7
TREF_TORQ_MIN_LIM
8
TREF_TORQ_MAX_LIM
9
FLUX_MIN_LIM
10
FREQ_MIN_LIMIT
11
FREQ_MAX_LIMIT
12
DC_UNDERVOLT
13
DC_OVERVOLT
14
TORQUE LIMIT
15
FREQ_LIMIT
Table 18 Follower MCW (Actual Signal 02.25)
Bit
Name
0
DRIVE ENABLED
1
Reserved
2
REVERSE CMD
3
DRIVE RUNNING
4
DIAMETER RESET
5
Reserved
6
HEARTBEAT
7
FAULT RESET CMD
8...15
Reserved
Active Limit
Pull-out limit.
Speed control torque min. limit.
Speed control torque max. limit.
User-defined current limit.
Internal current limit.
Any torque min. limit.
Any torque max. limit.
Torque reference min. limit.
Torque reference max. limit.
Flux reference min. limit.
Speed/Frequency min. limit.
Speed/Frequency max. limit.
DC undervoltage limit.
DC overvoltage limit.
Any torque limit.
Any speed/frequency limit.
Description
See chapter
Actual signals and
See chapter
Actual signals and
See chapter
Actual signals and
See chapter
Actual signals and
See chapter
Actual signals and
parameters, parameter 16.01.
parameters, parameter 10.02.
parameters, parameter 10.01.
parameters, parameter 65.03.
parameters, parameter 16.04.
Fieldbus control
159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-u2Acs800-u7Acs800-u4

Table of Contents