Information - ABB ACS800 Series Firmware Manual

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
ABS LOW LIM
32.02 SPEED1 LIMIT
-18000...18000 rpm
32.07 TORQUE1 FUNCTION
NO
LOW LIMIT
HIGH LIMIT
32.08 TORQUE1 LIMIT
-600.0...600.0%
32.09 TORQUE2 FUNCTION
32.10 TORQUE2 LIMIT
32.11 REF1 FUNCTION
NO
LOW LIMIT
HIGH LIMIT
32.12 REF1 LIMIT
0...18000 rpm

33 INFORMATION

33.01 SOFTWARE VERSION
33.02 APPL SW VERSION
33.03 APPL RELEASE DATE
33.04 BOARD TYPE
Description
Supervision wakes up if the value is below the set limit. The limit is
supervised in both rotating directions. The figure below illustrates the
principle.
speed/rpm
ABS LOW LIMIT
-ABS LOW LIMIT
Defines the speed supervision limit. See
Value of the limit
Activates/deactivates the motor torque supervision function and
selects the type of the supervision limit.
See
32.01
SPEED1 FUNCTION.
See
32.01
SPEED1 FUNCTION.
See
32.01
SPEED1 FUNCTION.
Defines the limit for the motor torque supervision (see
TORQUE1 FUNCTION).
Value of the limit in percent of the motor nominal torque
See
32.07
TORQUE1 FUNCTION
See
32.08
TORQUE1 LIMIT
Activates/deactivates the external reference REF1 supervision
function and selects the type of the supervision limit.
See
32.01
SPEED1 FUNCTION.
See
32.01
SPEED1 FUNCTION.
See
32.01
SPEED1 FUNCTION.
Defines the limit for REF1 supervision (see
Value of the limit
Program version, serial number.
Note: These values are READ-ONLY.
Displays the type and the version of the firmware package in the drive. -
Decoding key:
Product Family
B = US ACS800
Product
J = ACS800 Winder control program
Firmware Version
xxyx = Version 3.xyx
Displays the type and the version of the control program.
Displays the date the firmware was released.
Shows the control board type.
Note: RMIO-Ix boards have different type of FLASH memory chips
than RMIO-0x. Only software version BJXR3500 or later will operate
with RMIO-1x boards.
0
32.01
SPEED1 FUNCTION.
32.07
32.11
REF1 FUNCTION).
BJxxxxyx
Actual signals and parameters
97
FbEq
4
1 = 1 rpm
1
2
3
10 = 1%
1...3
10 = 1%
1
2
3
1 = 1 rpm
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-u2Acs800-u7Acs800-u4

Table of Contents