Table 8 Pack Status Bits (Actual Signal 03.15)
Bit
Name
0
WEB LOSS DETECTED
1
AT CORE DIAMETER
2
AT FULL DIAMETER
3
Reserved
4
Reserved
5
DANCER/TENSION CTRL
ON
6
WEB2 SELECTED
7
DANCER/TENSION
STALL ON
8
TORQUE MODE ON - NO
TRIM
9
TORQUE MEMORY ON
10
TORQUE BOOST ON
11
DIAMETER > LIMIT 1
12
DIAMETER > LIMIT 2
13
DIAMETER < LIMIT 1
14
DIAMETER < LIMIT 2
15
Reserved
Description
A web loss has been detected. See chapter
and
parameters, parameters
The calculated diameter equals the core diameter. See
chapter
Actual signals and
The calculated diameter equals the max roll diameter. See
chapter
Actual signals and
The drive is running and the PI regulator is controlling web
tension. See chapter
Actual signals and
parameters
62.09
and 63.09.
Web 2 has been selected and the corresponding gain, I-
Time and web dimensions are being used. See chapter
Actual signals and
parameters, groups
CONTROLS
and
63 TENSION
The web tension control is using the stall setpoints. See
chapter
Actual signals and
DANCER CONTROLS
and
The drive is operating in open loop torque mode. See
chapter
Actual signals and
and 63.16.
The drive is reading the current torque value and storing it.
See chapter
Actual signals and
66.01
and 66.02.
The drive is using the memorized torque value x the torque
boost. See chapter
Actual signals and
parameters 66.03...66.05.
The calculated diameter is greater than the user defined
limit. See chapter
Actual signals and
parameter 65.16.
The calculated diameter is greater than the user defined
limit. See chapter
Actual signals and
parameter 65.17.
The calculated diameter is less than the user defined limit.
See chapter
Actual signals and
65.18.
The calculated diameter is less than the user defined limit.
See chapter
Actual signals and
65.19.
Actual signals
60.03
and 60.04.
parameters, parameter 65.01.
parameters, parameter 65.02.
parameters,
62 DANCER
CONTROLS.
parameters, groups
62
63 TENSION
CONTROLS.
parameters, parameters
63.15
parameters, parameters
parameters,
parameters,
parameters,
parameters, parameter
parameters, parameter