System Commands - IBM 4610 SureMark GR3 Programming Manual Supplement

Fiscal printer turkey
Table of Contents

Advertisement

5.12.1 00 - SYSTEM COMMANDS

5.12.1.1 Command Format
-----------------------------------------------------------------------
BYTE BIT CONTENT
0
00 - System Commands
1
Options
10 = Fiscal Unit Test
20 = Report Current Status
40 = Fiscal Unit Power-On Reset
80 = Report Microcode EC Level
-----------------------------------------------------------------------
System commands are processed as follows:
Fiscal Unit Test
FU test is performed and then the FU status is sent over the serial communication link.
Report Current Status
The FU current status is sent over the serial communication link.
Fiscal Unit Power-On Reset
The microcode performs a FU software POR.
Report Microcode EC Level
The FU status containing the microcode EC level in byte 8 (the usual FU return code byte) is sent over
the serial communication link.
If command byte 1 is different than those defined above, no processing is performed and no response is sent.
5.12.1.2 System Commands Rules
This command cannot be used by applications using the IBM device drivers.
It is intended for device driver use only.
TYPE
LENGTH
hex
1
hex
1
hex
1
Command Set Reference — Page 143 of 183