Table of contents
6.2
Fail-safe operation ................................................................................................................. 58
6.3
Fault-tolerant automation systems (redundancy operation) .................................................. 61
6.3.1
Redundant SIMATIC automation systems ............................................................................. 61
6.3.2
Increase of plant availability, reaction to errors ..................................................................... 62
6.4
Introduction to the I/O link to fault-tolerant system ................................................................ 65
6.5
Using single-channel switched I/O ......................................................................................... 66
6.6
Versions of I/O connection to the PROFINET IO interface .................................................... 73
6.6.1
6.6.2
Redundant I/O in an ET 200SP HA ....................................................................................... 76
6.7
Connection of two-channel I/O to the PROFIBUS DP interface ............................................ 80
6.7.1
Connecting redundant I/O ...................................................................................................... 80
6.7.2
Signal modules for redundancy ............................................................................................. 83
6.7.3
Evaluating the passivation status ........................................................................................... 97
6.8
Media redundancy ................................................................................................................. 97
7
System and operating states of the CPU 410 ....................................................................................... 101
7.1
CPU 410 operating modes ................................................................................................... 101
7.1.1
RUN mode ........................................................................................................................... 101
7.1.2
STOP mode ......................................................................................................................... 102
7.1.3
STARTUP mode .................................................................................................................. 103
7.1.4
HOLD mode ......................................................................................................................... 104
7.1.5
LINK-UP and UPDATE modes ............................................................................................ 105
7.1.6
ERROR-SEARCH mode ...................................................................................................... 105
7.1.7
DEFECTIVE state ................................................................................................................ 106
7.2
System states of the redundant CPU 410 ........................................................................... 107
7.2.1
Introduction .......................................................................................................................... 107
7.2.2
The system states of the fault-tolerant system .................................................................... 109
7.2.3
7.2.4
System status change from the STOP system state ........................................................... 110
7.2.5
System status change from the standalone mode system status ....................................... 111
7.2.6
System status change from the redundant system state ..................................................... 111
7.2.7
System diagnostics of a fault-tolerant system ..................................................................... 112
7.3
Self-test ................................................................................................................................ 114
7.4
Performing a memory reset ................................................................................................. 117
8
Link-up and update .............................................................................................................................. 119
8.1
Effects of link-up and updating ............................................................................................. 119
8.2
Link-up and update via an ES command ............................................................................. 120
8.3
Time monitoring ................................................................................................................... 120
8.3.1
Time response ..................................................................................................................... 123
8.3.2
Determining the monitoring times ........................................................................................ 123
8.3.3
Performance values for link-up and update ......................................................................... 130
8.3.4
Influences on time response ................................................................................................ 130
8.4
Special features in link-up and update operations ............................................................... 131
4
CPU 410 Process Automation/CPU 410 SMART
System Manual, 05/2017, A5E31622160-AC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic 410 smartSimatic pcs 7

Table of Contents