Siemens SINUMERIK 802S Start-Up page 26

Hide thumbs Also See for SINUMERIK 802S:
Table of Contents

Advertisement

Installing the Control System
2.3
Connecting the individual components
Connector designation:
Connector type:
Table 2-5
Pin
Signal
1
SW
2
3
4
5
RF.2
for analog drives:
SW
BS
RF.1, RF.2
Signal type
VO
K
Drives with analog interface
Signals:
One voltage and one enable signal is provided.
S
SW (SETPOINT)
Analog voltage signal in the range of "10 V to output a speed setpoint
S
BS (REFERENCE SIGNAL)
Reference potential (analog ground) for the setpoint signal, internally connected to the log-
ics ground
S
RF (SERVO ENABLE)
Relay contact pair used to switch the enable signal for the power section, e.g. a
SIMODRIVE unit. This signal is used by the ENC when the cyclic control mode is started.
Signal parameters
The setpoint is output as an analog differential signal.
Table 2-6
Voltage range
Output current
Relay contact
2-26
X3
SPINDLE
9–pin D-Sub plug connector
Belegung des Steckers X3
Type Pin
Signal
VO
6
BS
7
8
9
RF.1
K
Setpoint
Reference potential for setpoint (analog ground)
Servo enable contact
Voltage output
Switching contact
Electrical parameters of the spindle setpoint signal
Parameter
X3
Type
VO
6
9
9
K
Min.
-10.5
10.5
-3
3
6FC5 597–2AA00–0BP2 (01.02)
1
5
5
Max.
Unit
V
mA
SINUMERIK 802S

Hide quick links:

Advertisement

Table of Contents
loading