Start-Up
4.7
Commissioning
4.8

Series machine start-up

Functionality
The objective of series machine start-up is:
S
after commissioning, in order to bring another control system connected to the same ma-
chine type with minimum effort to the condition as after commissioning;
or
S
under service conditions (after replacing hardware components), to bring a new control
system to the initial state with minimum effort.
Precondition
To carry out commissioning, a PC/PG provided with a V24 interface for data transfer from/to
the control system is necessary.
In the PC/PG, the WinPCIN tool must be used.
Sequence of operations
1. Create the series machine start-up file (transfer from the control system to the PC/PG).:
– Make a V24 cable connection between the PC/PG (COM port) and the SINUMERIK
802S (X8).
– Make the following settings in the WinPCIN tool:
– – Binary format
– Receive data
– Select the path where you want to save your data
– Save
– The PC/PG will set itself to "Receive" and will wait for data from the control system.
– Enter the password for protection level 2 in the control system.
– Call the Services/RS232 setting menu.
– Select the Start-up data line from the Services menu and press Start data outp. to
output the series machine start-up file.
2. Reading in the series machine start-up file into the SINUMERIK 802S:
– Enter the V24 interface settings as described under 1).
– Press the Data In Start button in the Service menu. The control system is thus ready
to receive data.
– Use the PCIN tool in the PC/PG to select the series start-up file from the DATA_OUT
menu and start data transfer.
– The control system is brought to "RESET with rebooting" three times during and at the
end of data transfer. On completion of error-free data transfer, the control system is
completely configured and ready to operate.
4-102