Installation
Horizontal Termination with One 90° Elbow
YOU MUST PUT A MINIMUM 2' VERTICAL SECTION (3' FOR LP)
ON TOP OF THE STOVE BEFORE ELBOW
If using a Snorkel Termination (14" (356mm) or 36" (915mm)) add the snorkel height to the vertical
height (snorkel terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
19' max (5.8m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
© Travis Industries
(for qualified installers only)
Restrictor Position # 5
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
NATURAL GAS: Min. 2' (0.61m) Section Required
PROPANE (LP): Min. 3' (0.915m) Section Required
12/27/2018 - 1440
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
Berkshire GSR2 3-Sided
15
19' max (5.8m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet