Stove Installation
Chimney Termination Requirements
Must have an approved cap (to prevent water from entering)
Must not be located where it will become plugged by snow or other material
Must terminate at least 914mm (3') above the roof and at least 610mm (2') above any portion of the
roof within 3.048 meters (10') (see Figure 2)
Slanted Roofs
Chimney must
extend 3'
above the roof
Flat Roofs
Outside Air Requirements
Must not be drawn from an enclosed space (garage, unventilated crawl space)
Requires a 76.2mm (3") duct that attaches to the back of the stove (see "a" below).
Outside air duct must have a rodent screen and rain hood (see "b" below).
The Travis Industries Outside Air Kit (SKU 99200139) includes all the above components.