Addendum To Rev. B - KVH Industries TracVision 6 Technical Manual

Satellite television
Hide thumbs Also See for TracVision 6:
Table of Contents

Advertisement

TracVision 6 Technical
Manual Addendum
(ECO #s 5959, 5503, 5315, 6138, 6198)
The following changes have been made to Revision B of the
TracVision 6 Installation and Technical Manual (KVH Part
Number 54-0166).
3.1.1 Blown Fuse, Low Power, or Wiring
The 4-amp fuse on the
CPU Printed Circuit Board (PCB)
replaced with two 3.15-amp fuses to better protect the Antenna Unit's
electronics.
1. Blown Fuse – The Antenna Unit is equipped with
two fuses mounted on its CPU Board. If either of
these fuses has blown or been broken, the
Antenna Unit will not operate. Refer to Section 4.4,
"PCB Removal and Replacement," for details on the
fuse locations and how to access the CPU Board.
4.3
TracVision 6 Field
Replaceable Units
Table 4-1 has been updated to show the new part number for the
3.15-amp fuses and the new part numbers for the RF Detector PCB and
European LNB. The azimuth limit switch has also been added to the
list.
FRU
Radome
CPU
RF Detector PCB
Antenna Gyro Sensor
Antenna Gyro Gasket
Elevation Drive Belt
Elevation Motor
Azimuth Limit Switch Assembly

54-0166 Addendum to Rev. B

has been
Part Number
02-1047-01
02-0992
02-1237
02-1035
24-0139
24-0105-83
02-1050
02-0957-01
Table 4-1
TracVision 6 Field
Replaceable Units