Tracvision 6 Antenna Unit (Baseplate Cut Away); Figure; Figure 4-1 Tracvision 6 Antenna Unit (Baseplate Cut Away) - KVH Industries TracVision 6 Technical Manual

Satellite television
Hide thumbs Also See for TracVision 6:
Table of Contents

Advertisement

FRU
RF Cable
PC Cable
CPU Fuse
The Antenna Unit printed circuit boards, Antenna LNB, elevation
stepping motor, and elevation drive belt may be removed and
replaced on site using common hand tools. Other TracVision 6
service must be done by your authorized dealer/installer,
distributor or by KVH. Evidence of tampering or unauthorized
repairs will void the warranty. The following are step-by-step
procedures for removing and replacing those components that
may be serviced.
Figure 4-1 depicts the location of a number of components within
the TracVision 6 Antenna Unit.
U.S./Galaxy-style
Elevation Motor
and Drive Assembly
PCB Cover
and PCBs
54-0166 Rev. B
Part Number
32-0566-0100
32-0628-06
16-0017-4000
LNB
Table 4-1 (continued)
TracVision 6 Field
Replaceable Units
To help us continually improve the
quality and reliability of our
systems, please return any failed
component to KVH or KVH Europe
after you receive your replacement
part.

Figure 4-1

TracVision 6 Antenna Unit
(Baseplate Cut Away)
European LNB
Antenna Gyro
Azimuth Motor
Maintenance
4-3

Advertisement