Connections

Connections for the Dual Camera Operation

Other than the optical-fiber cables, all cables are 75-ohm coaxial cables with BNC connectors.
Primary camera
BVP-9500WS/9500WSP/950/950P 1
Serial
OUT
Video signal
Serial
IN
Secondary camera
BVP-9500WS/9500WSP/
950/950P 2
External power supply
20
CA-950/950P
Optical-fiber cable
Serial
IN
SDI AUX OUT
Return video signal
Video signal
(Coaxial cable with
BNC connector)
Serial
OUT
SDI AUX IN
CA-950/950P
Notes
• The primary system and the secondary system must be gen-locked.
• If the BVP-9500WS/9500WSP is operated at triple speed, dual camera
operation is released, and the secondary system cannot be used.
Secondary CCU
CCU-900/900P 1
SDI AUX IN
Return video signal
(Coaxial cable with
BNC connector)
SDI AUX OUT
Secondary CCU
CCU-900/900P 2
REFERENCE
IN
••••
• •
••
••
• ••••••
RCP-700-series
Remote Control
Panel
REFERENCE
IN
••••
• •
••
••
• ••••••
Reference signal
RCP-700-series
Remote Control
Panel