Location and Function of Parts
4 -AC IN (AC power supply input) connector
Connect to an AC power supply using the supplied AC
power cord. The power cord is fixed to the CCU-900/
900P using the supplied plug holder.
5 Remote control connectors
A AUX 1/AUX 2 (auxiliary 1/auxiliary 2)
connectors (D-sub 9-pin, RS-422)
Used to connect the CCU-900/900P and external
equipment via an RS-422 interface.
B MIC REMOTE (microphone remote) connector
(D-sub 15-pin)
Using this connector, the video camera's microphone
input level may be set from external equipment such as
an audio mixer in five steps (–60, –50, –40, –30, and
–20 dB). When recording, set the volume to an
appropriate level for the audio conditions.
Outputs red and green tally signals.
The microphone input level can be set using switches on an
internal board. For more information on setting the
switches, contact a Sony service representative.
C WF MODE (waveform monitor mode)
connector (D-sub 15-pin)
Used to connect a cable from the appropriate
connector on a waveform monitor when operating the
waveform monitor display using an MSU-700A/750
Master Setup Unit or RCP-700-series Remote Control
Panel. When using a recall-type monitor, preset a
display mode on the waveform monitor, and then
recall the mode externally.
12
A AUX 1/AUX 2 connectors
B MIC REMOTE connector
C WF MODE connector
AUX 1
WF MODE
AUX 2
MIC REMOTE
D WF MODE connector
E RCP/CNU connector
F TRUNK LINE 1/TRUNK LINE 2 connectors
TRUNK LINE 1
RCP/CNU
TRUNK LINE 2
D WF MODE (waveform monitor mode output)
connector (4-pin)
Used to connect a cable from the appropriate
connector on a waveform monitor when monitoring a
signal in sequential mode. A sequence signal will be
output when the SEQ button on the RCP-700-series
Remote Control Panel is pressed, allowing
simultaneous monitoring of the R, G, and B signals in
sequential mode.
For information about these operations, refer to the
Operation Manual supplied with the Remote Control Panel.
E RCP/CNU connector (8-pin)
Used to connect to an MSU-700A/750 Master Setup
Unit, CNU-500/700 Camera Command Network Unit,
or RCP-700-series Remote Control Panel using a
CCA-5 Connection Cable. Control signals are sent
and received via this connector. When using an RCP-
700-series unit, power is also supplied.
F TRUNK LINE 1/TRUNK LINE 2 connectors
(D-sub 9-pin, RS-232C)
Used to connect the CCU-900/900P to the TRACKER
connector (20-pin) on a CA-950/950P Camera Adaptor
via an RS-232C interface. Used mainly for
communication with equipment on the camera side.
The RXD, TXD, RTS, and CTS signals can be
transferred at up to 9600 bps using this connector.
The TRUNK LINE 2 connector is provided for
extension.