Figure 20 Location Of Auxiliary Switches - Honeywell HercuLine 10260S Installation, Operation And Maintenance Manual

Smart actuator
Table of Contents

Advertisement

4. Set Up and Calibration Procedures - Setting Auxiliary Switches (actuators mfd. pre-1/1/03)
4. Once the cams are set in the correct positions, turn the locking nut clockwise until snug tight (it does
not have to be "hard" tight and does not have to completely flatten the spring washer).
5. Double check limit switch actuation by first manually driving the actuator to each end of travel and
hearing the switch click or by detecting it with a continuity tester. Secondly, drive the actuator to both
ends of travel (using the auto/manual switch or by providing minimum and full input signal) and make
sure the switches activate.
Revision 5
10260S HercuLine® Actuator Installation, Operation and Maintenance Manual
7/07
L O CK ING
NUT

Figure 20 Location of Auxiliary Switches

CA M 1 (RE F)
CA M
S LO T S
S WIT CH 1
S WIT CH 3
S WIT CH 5
NO T E : S wi tc h e s 2 , 4 a n d 6
a re l o c a te d o n l e ft si d e .
71

Advertisement

Table of Contents
loading