B. Wiring Requirements
IntelliFire™ Touch Ignition System Wiring
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance power cord to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 6.2, IntelliFire
Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Ensure the 6 volt transformer is plugged into the supplied
cord assembly to supply power to the unit OR install 4 AA
cell batteries (not included) into the battery pack before
use.
• Reset switch must be installed and in the "ON" position
for appliance to operate.
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
2166-302 (NG)
2166-303 (LP)
Figure 6.2 IntelliFire™ Touch Wiring Diagram
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
28
Touch (IPI) Wiring
TM
FLAME
IGNITER
SENSE
2550-013 (NG)
2550-014 (LP)
6V TRANSFORMER
PLUG
2179-300
S
I
2326-150
2326-130
RF MODULE
2326-120
6 PIN
BLK
BRN
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
WSK-21-W
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service. Store battery pack in
appliance manual bag when not in use.
Halogen Lights
Halogen lights are factory installed.
Note: Not offered with 25 in. model.
Battery Pack
Battery pack is not factory installed in appliances. See
appliance manual bag for battery pack. Battery pack
should only be installed during power outages.
TO CORD ASSEMBLY 110-120 VAC
2326-131
WIRE ASSEMBLY
2159-310
TO CORD
ASSEMBLY
110-120 VAC
2326-152
RED
2326-132
BATTERY PACK
RED
BLK
BLK
SPLITTER
2187-198
(OPTIONAL)
2206-299
* MODULE RESET SWITCH
(LOCATED ON SURROUND)
* Reset switch must be installed
and in the "ON" position for
appliance to operate.
FAN 110-120 VAC
GFK-160A
LIGHT WIRE
ASSEMBLY
2532-017