Hearth Extension - Quadra-Fire EXCURSION-I Installation Manual

Hide thumbs Also See for EXCURSION-I:
Table of Contents

Advertisement

Mantels - Combustible
Figure 3.15 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible
E. Hearth Extension
1/2 in.
Figure 3.16 Minimum Required 1/2 in. Gap to Bottom of Front
• Combustible flooring may be located in front of the
appliance. Exception - no vinyl / adhesive flooring.
See Figure 3.17.
• 1/2 inch gap under the bottom of the front must be
maintained. See Figure 3.16.
• A minimum 1/4 inch gap from the bottom of the appliance
to the metal floor of the solid fuel firebox is REQUIRED.
See side view in Figure 3.18.
• Combustible flooring underneath the appliance is
acceptable with a 1/4 inch gap. See Figure 3.18.
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
18
12 in.
12 in.
Measurement to bottom
Measurement
of appliance:
from surround
= 29-1/4 in. (25")
opening.
= 32-3/4 IN. (30")
= 36-1/4 IN. (35")
Y
NO VINYL /
ADHESIVE FLOORING
Figure 3.17 Hearth - Combustible Material Exception
Vinyl / Adhesive Flooring - Minimums
Appliance Size
Depth (X)
25 in.
30 in.
35 in.
SIDE VIEW
MINIMUM 1/4 IN. REQUIRED
COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE
Figure 3.18 Solid Fuel Floor Clearance
X
Width (Y)
16 in
25-3/4 in.
16 in
30-3/4 in.
16 in
35-3/4 in.

Hide quick links: