Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• This appliance comes with a 120 VAC cord assembly.
This is required for proper operation of the appliance
(IntelliFire Ignition). An outlet box may be installed in
a bottom back corner of the existing solid fuel masonry
or factory built fi replace to plug in the cord assembly,
or the supplied power cord may be routed out onto the
hearth to a nearby outlet.
• A 120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
• Low voltage and 120 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
120V to the valve or to the appliance wall switch. Incor-
rect wiring will damage controls.
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
MODULE RESET
SWITCH
2206-299
WIRE ASSEMBLY
TO CORD ASSEMBLY
120VAC
Figure 10.1 IPI Wiring Diagram
26
INTERMITTENT
PILOT IGNITOR
2201-030
MODULE
ORG
WALL SWITCH
WHT
JUMPER WIRE
2179-300
BLACK
RED
ORANGE
GREEN
(PILOT)
(MAIN)
Quadra-Fire • QFI30FB, QFI35FB • 2221-900 Rev. K • 3/11
B. IntelliFire Plus
• Wire an outlet box (120VAC) in the bottom back corner of
the existing solid fuel masonry or factory built fi replace to
plug in the cord assembly, or the supplied cord assembly
may be rerouted out onto the hearth to a nearby outlet
for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 10.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
control valve which operates on a 6 volt system.
• Plug the 6 volt transformer plug into the appliance cord
assembly to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery tray before use.
See Section 2.H for instructions on locating battery tray
and installing batteries.
• Battery longevity and performance will be affected by
the service temperatures of this appliance. Batteries
should only be used as a power source in the event of an
emergency such as an outage.
AUX WIRE EXTENSION
(2201-155)
BATTERY PACK
6V DC (AA X 4)
GROUND
TM
Ignition System Wiring
RC300 4.5V DC
(AA X 3)
FAN
AUX 300
AUX2 NOT USED FOR INSERT MODELS.
MODULE
PROTECTIVE COVER INCLUDED.
FAN
AUX1 AUX2
TO CORD ASSEMBLY
120VAC
LIGHT WIRE ASSEMBLY
(2201-013)
EMBER BULB 20W (2)
(2088-136)
ACCENT SOCKETS (2)
(2146-402)
TM